DMU-09

DMG MORI DMU 50 (3rd Generation) · Heidenhain TNC 640 · Bay 3 · Cell A · s/n DMU50-22970

Live machine view
Five-axis cycle
X/Y/Z, the swivelling B trunnion and the C rotary table follow live telemetry; the door opens when the machine stops. Drag to rotate, scroll to zoom.
Cutting
Effectiveness
OEE this shift
Night (22:00–06:00) · 338 of 357 min running
81%

Availability

94.7%

Performance

85.2%

Quality

100.0%

Current job
WO-24152
Blade root fixture · NT-6650-A

Pieces

23 / 24

Cycle time

5m 40s

This piece

3m 18s elapsed

Operator

Arden Adams

Tool

T5 · Ø8 ball nose

Tool life left

71%

Finishes

29 Oct 04:02

Losses
Downtime by reason
19.0 minutes lost this shift, biggest first.

Setup / first-off

8.9 min

Tool change

3.4 min

No material

2.5 min

Waiting QA

1.9 min

No operator

1.2 min

Breakdown

1.1 min

Quality
Pieces this shift
Ideal 276 s versus actual 324 s per piece.

Good

62

Scrap

0

Rework

0

OEE per hour · %

Queue
Jobs on this machine (4)
The job on the spindle and everything queued behind it, earliest due date first.

WO-24152

Brunner Hydraulik · NT-6650-A OP20 · Inconel 718 · setup 102 min

Running

23/24 · due 29 Oct 18:56

WO-24153

Vogt Optics · AD-3310-A OP30 · Al 7075-T6 · setup 71 min

Queued

0/40 · due 30 Oct 05:56

WO-24156

Brunner Hydraulik · BH-9021-D OP10 · Al 6082 · setup 89 min

Queued

0/24 · due 30 Oct 23:56

WO-24160

Nordwind Turbinen · VO-2075-A OP10 · Invar 36 · setup 74 min

Queued

0/40 · due 01 Nov 23:56

Readings
Live telemetry
Polled every 5 seconds · spindle 15,276 h, service in 658 h

Spindle load

70 %

Spindle speed

9,026 rpm

Feed rate

1,328 mm/min

Spindle temp

49.4 °C

Coolant temp

27.3 °C

Coolant pressure

19.1 bar

Vibration

1.9 mm/s

Axis load B

31 %

Axis positions

X

84.2

Y

136.7

Z

-88.4

B

-11.8

C

177.2

Spindle history
Spindle load, speed and vibration

Spindle load · %

Spindle speed · rpm

Vibration · mm/s

Alarms
Alarms (8)

C axis following error

Alarm 1188 · 10-29 01:25

Low

Spindle lubrication cycle overdue

Alarm 2214 · 10-28 23:55

High

Tool life expired on T7, change required

Alarm 2019 · 10-28 19:11

High

Probe measurement out of tolerance

Alarm 5502 · 10-28 10:18

Medium

Coolant level low in the tank

Alarm 7014 · 10-28 08:28

High

Chip conveyor jammed

Alarm 3320 · 10-27 14:35

Medium

Tool life expired on T7, change required

Alarm 2019 · 10-27 04:43

Medium

Coolant level low in the tank

Alarm 7014 · 10-27 03:59

Medium