DMU-03

DMG MORI DMU 50 (3rd Generation) · Siemens SINUMERIK ONE · Bay 1 · Cell C · s/n DMU50-24099

Live machine view
Five-axis cycle
X/Y/Z, the swivelling B trunnion and the C rotary table follow live telemetry; the door opens when the machine stops. Drag to rotate, scroll to zoom.
Cutting
Effectiveness
OEE this shift
Night (22:00–06:00) · 388 of 413 min running
74%

Availability

93.8%

Performance

79.5%

Quality

98.8%

Current job
WO-24114
Bracket, actuator · AD-3310-A

Pieces

40 / 40

Cycle time

4m 56s

This piece

3m 13s elapsed

Operator

Arden Adams

Tool

T5 · Ø8 ball nose

Tool life left

42%

Finishes

—

Losses
Downtime by reason
25.6 minutes lost this shift, biggest first.

Setup / first-off

10.8 min

Tool change

4.7 min

No material

3.8 min

Waiting QA

2.9 min

No operator

1.7 min

Breakdown

1.7 min

Quality
Pieces this shift
Ideal 228 s versus actual 287 s per piece.

Good

80

Scrap

1

Rework

0

OEE per hour · %

Queue
Jobs on this machine (3)
The job on the spindle and everything queued behind it, earliest due date first.

WO-24114

High

Helvetica Medtech · AD-3310-A OP10 · Al 7075-T6 · setup 112 min

Late

40/40 · due 29 Oct 00:53

WO-24115

Aerodyn Systems · NT-6650-A OP20 · Inconel 718 · setup 55 min

Queued

0/40 · due 30 Oct 19:53

WO-24116

Sandvik Tooling · ST-3390-A OP30 · H13 tool steel · setup 96 min

Queued

0/24 · due 31 Oct 14:53

Readings
Live telemetry
Polled every 5 seconds · spindle 18,506 h, service in 343 h

Spindle load

77 %

Spindle speed

8,589 rpm

Feed rate

1,720 mm/min

Spindle temp

50.2 °C

Coolant temp

27 °C

Coolant pressure

19.1 bar

Vibration

2.11 mm/s

Axis load B

25 %

Axis positions

X

140.0

Y

113.9

Z

-111.0

B

-10.0

C

236.8

Spindle history
Spindle load, speed and vibration

Spindle load · %

Spindle speed · rpm

Vibration · mm/s

Alarms
Alarms (8)

Door interlock opened during cycle

Alarm 6621 · 10-29 03:25

High

B axis drive temperature high

Alarm 1105 · 10-29 02:35

Medium

Tool life expired on T7, change required

Alarm 2019 · 10-29 02:13

Low

B axis drive temperature high

Alarm 1105 · 10-28 08:44

Medium

Tool life expired on T7, change required

Alarm 2019 · 10-28 02:38

High

Coolant level low in the tank

Alarm 7014 · 10-27 13:03

High

Coolant level low in the tank

Alarm 7014 · 10-27 12:16

High

Coolant level low in the tank

Alarm 7014 · 10-27 08:21

High